Due to In-Circuit Test issues probing difficult to penetrate processes such as Pb-free solder,OSP (Organic Solderability
Preservative),Immersion Au (Gold),Ag (Silver),Sn (Tin) and No-Clean,as well as the different manufacturing process
variations like wave,select wave and reflow (single and double),new innovative razor sharp probe tip styles were developed
(Figure 1). It was determined that a probe tip that has the qualities of a sharp blade edge would help to penetrate these problem processes. Edge sharpness has been determined to be a critical factor in the successful penetration of these processes within via and test pad applications. In addition,due to the sharpness of the edge,the penetration is effective even off center of the test via or in the pad area as well. Most tips used to probe vias today contain a single point design with the mentality that this sharp single point will break thru these board processes/contaminants. However,in most cases a single point probe will bottom out in the pool of flux contained within the via resulting in poor electrical contact. A razor sharp tip style will better penetrate these hard to probe fluxes and contaminants without bottoming out. Typically,Test Engineers
would be forced to increase the probe spring force to break-through these contaminants,but high-density PCB’s do not allow
the use of higher spring forces due to the increased possibility of board flex which can cause damage to expensive boards. The use of the razor sharp probes does not require a higher spring force and in some cases the spring force can be reduced. Because of these innovative tip styles,first pass yields are significantly increased,repeated fixture actuations are not needed,false failure rates and NDF’s (No Defects Found) are reduced,all of which results in less test time and faster board throughput which ultimately lowers board test costs.